UltraShield 2000 Liquid-Applied Waterproofing Membrane
TKH Ref:
TKH-M-AC-1013
Product Type
Material
Brand
AquaGuard
Brand / Model
US-2000
Key Highlight
Waterproofing product for roof, podium, wet area applications.
Material Category
tagMaterialCategory
System Category
systemCategory
System Tag
tag4SCategory
Performance Class
Crack-Bridging, UV Resistant
Fire Environment
Not Fire Rated
Section 1 - Overview
Product Name
UltraShield 2000 Liquid-Applied Waterproofing Membrane
Product Type
Material
Brand
AquaGuard
Brand / Model
US-2000
Manufacturing Origin
Germany
Overview Description
Demo material listing: UltraShield 2000 Liquid-Applied Waterproofing Membrane by AquaGuard (US-2000).
Key Advantages
- High Crack-Bridging, UV-Resistant
Typical Use Cases
- Roof, Podium, Wet Area
Section 2 - Technical Specifications
Density
1150 kg/m³
Thickness
1.5 mm (DFT per coat; system 1.5–2.0 mm)
Chloride Content
‚â§0.02%
Compressive Strength
Compressive Strength
Tensile Strength
≥2.0 MPa
Flexural Strength
Crack-bridging ≥1.5 mm (23°C)
Adhesion / Pull-off Strength
≥1.5 MPa (concrete, pull-off)
Slip Resistance
Slip Resistance
Pull-out Capacity
Pull-out Capacity
Acoustic Rating (dB)
Acoustic Rating (dB)
Mixing Ratio
Mixing Ratio
Pot Life
Pot Life
Curing Time
Touch dry 4–6 h; rain resistant 6–8 h; full cure 7 d (20°C)
Recommended Temperature
+5°C to +35°C application; service -20°C to +80°C
VOC / Emission
VOC Content
Service Environment
Roof/podium; UV topcoat recommended for exposed use
System Category
Environmental Performance
Core System Function
Environmental Performance
System Components
Environmental Performance
Connectivity Type
Environmental Performance
Data Output & Reporting
Environmental Performance
Integration Capability
Environmental Performance
Section 3 - Compliance & Certifications
Primary Standard
EN 1504-2
Compliance Summary
Compliant with EN 1504-2, ETAG 005 (project verification required).
Accredited Testing Required
Third-party performance testing is required to verify watertightness, crack-bridging capability and durability under service conditions.
Accredited Testing
Testing conducted by accredited laboratories in accordance with relevant EN and/or ETAG/EAD test methods for liquid-applied waterproofing systems.
Fire Class
Fire Class
Regulatory Requirements
Subject to acceptance by the project consultant and relevant authorities having jurisdiction based on submitted test reports and system approvals.
Potable Water Compatibility
Not intended for use in potable water applications unless specifically stated and approved.
Compliance
EN Standards
Standards & Compliance
tagCompliance
Section 4 - Documents
Technical Data Sheet (TDS)
Safety Data Sheet (SDS)
Certifications
Installation Manual
Application Guide
Method Statement
Test Reports
Fire Test Reports
Acoustic Reports
BIM Files
CAD Files
Product Specification Sheet
Section 5— Applications & System Details
Structural Applications
Structural Applications
Infrastructure Applications
Infrastructure Applications
Waterproofing Applications
Basements, podium slabs and water-retaining structures where joint and surface waterproofing is required.
Building Services / MEP
Plant rooms and service areas where leakage control is critical.
Finishing / Architectural
Finishing / Architectural
Special Applications
Special Applications
Deployment & Installation
systemDeployment
Power Supply
systemPower
Limitations & Constraints
systemLimitations
Section 6 — Technical Summary
Summary – Primary Standard
Accredited Testing Required
Summary – Key Performance
Accredited Testing Required
Summary – Fire
Accredited Testing Required
Summary – Environmental
Accredited Testing Required
Referenced Standard
Primary Standard
Compressive Strength
Compressive Strength
Flexural Strength
Flexural Strength
Tensile Strength
Tensile Strength
Adhesion / Pull-Off Strength
Adhesion / Pull-Off Strength
Slip
Slip
Pull-Out Capacity
Pull-Out Capacity
Mixing Ratio
Mixing Ratio
Pot Life / Working Time
Pot Life / Working Time
Curing Time
Curing Time
VOC / Emission
VOC / Emission
Chloride Content
Chloride Content
Section 6 - System Summary
Summary – Primary Standard
Accredited Testing Required
Summary – Key Performance
Accredited Testing Required
Summary – Fire
Accredited Testing Required
Summary – Environmental
Accredited Testing Required
Referenced Standard
Accredited Testing Required
System Category
Accredited Testing Required
System Function
Accredited Testing Required
System Components
Accredited Testing Required
Deployment & Installation
Accredited Testing Required
Power Supply
Accredited Testing Required
Connectivity & Communication
Accredited Testing Required
Data Output & Reporting
Accredited Testing Required
System Integration
Accredited Testing Required
Limitations & Constraints
Accredited Testing Required
Supplier Information

# Still not sure if this product fits your project?
Ask for application guidance, documentation, or technical clarification.
.png)











